Intelligent Krebs Stormer Viscometer

BGD 186 is the newest Krebs Viscometer which is upgraded from BGD 184. It is used widely for making viscosity measurements on paints/coatings in accordance with ASTM D562. Digital version with constant speed motor rotating at 200 r.p.m can get greater accuracy and repeatability for test results.

Comparing with BGD 184, it has these features as below:

◆ Can show “KU”, “cP”, “g”,  “℃” value simultaneously.

◆ Designed with calibration function: With standard oil, users can complete calibration independently, no need return it to manufacture.

◆ Biult in infrared thermometer sensor to measure sample temperature, more convenient and more precise.

◆ Has a big LCD which can show test result clearly

◆ Can set test time and show real time

◆ With RS 232 communication port, can print test results

◆ Self protection function under over-range.

◆ Magnetic rotor enables rapid installing, dismantlement or cleaning

◆ Come with Calibration Certificate


NOTE:

The cP reading from the Krebs Stormer Viscometer is not necessarily agree with cP values measured by other instruments due to:

1. Unique shear rate of the Krebs Stormer Viscometer paddle spindle.

2. Uniqueness of the Krebs unit scale

BGD 186

BGD 186-03.jpg





BGD 186-04.jpg


BGD 186-05.jpg


BGD 186-07.jpg


BGD 186-08.jpg


BGD 186-015.jpg


BGD 186-020.jpg


BGD 186-016.jpg


Main Technical Parameters

■ Range: 40.2KU~141.0KU     27-5,250 cP
■ Accuracy:±1.0% of full scale range
■ Repeatability:±0.5% of full scale range
■ Paddle Speed:200r/min±0.1r/min
■ Overall Dimensions:210mm×180mm×500mm(length by width by height )

■ Package Size:560mm×450mm×280mm

■ Package Weight:9.2 KG

■ Ordering Information:BGD 186---Intelligent Krebs Stormer Viscometer

BGD 186/J-042----Special Paddle for Paste

BGD 1600/Z-012---Standard Oil for Krebs Stormer Viscometer (67.2 KU)

BGD 1600/Z-013---Standard Oil for Krebs Stormer Viscometer (86.3 KU)

BGD 1600/Z-014---Standard Oil for Krebs Stormer Viscometer (106.6 KU)

BGD 1600/Z-015---Standard Oil for Krebs Stormer Viscometer (121.5 KU)


Introduction

Operation

Subject:
Company:*
Name:
E-mail:*
Country:*
Comments:
Verification Code:Click ChangeCan't see clearly. Change it?
 
Send message
Contact USMore

Biuged Precise Instruments (Guangzhou) Co.,Ltd

Add:NO.15, Fuzhong Rd., Zhongxin Town, 

Zengcheng District, Guangzhou.China

Tel:+86-20-32955999;+86-20-32955820

Fax:+86-20-32955819 

E-mail:jack@biuged.com

Website: http://www.biuged.com 


Biuged Instruments Co.,Ltd.

Add:RM.310, NO.1, Sicheng Rd.,
Tianhe District, Guangzhou.China

Tel:+86-20-82169666

Fax:+86-20-32955818

E-mail:jack@biuged.com





Biuged Precise Instruments (Shanghai) Co.,Ltd

Add:Room 906, 9th Floor, Zhongcai Industrial Park, No.1111 

Zhu Feng Road, Qingpu District, Shanghai, China

Tel:+86-21-59240298

Fax:+86-21-59249719

E-mail:xjx@biuged.com

  Biuged Laboratory Instruments (Guangzhou) Co., Ltd.   Guangdong ICP record number:11044672